This manual applies to fiber amplifier. It mainly describes the performance characteristics, technical parameters, installation and debugging, common troubleshooting, and other related content of the product.In order to ensure that the equipment can be successfully installed and safely operated, please read this manual carefully before installing and debugging the equipment. And the installation and debugging should be strictly according to the specified steps on the manual to avoid unnecessary damage to equipment or accident harm to the operator. Any questions, please contact with us in time.
Special Tips:
​
4.1
Item |
Unit |
Technique parameters |
Remark |
|
Operating bandwidth |
nm |
1545 - 1565 |
||
Optical input power range |
dBm |
-3 - +10 |
Max range: -10-+10 |
|
Optical Switching time |
ms |
≤ 5 |
||
Maximum optical output power |
dBm |
41 |
||
Output power stability |
dBm |
±0.5 |
||
Noise figure |
dB |
≤ 6.0 |
Optical input power 0dBm, λ=1550nm |
|
Return loss |
Input |
dB |
≥ 45 |
|
Output |
dB |
≥ 45 |
||
Optical Connector Type |
CATV IN:SC/APC, PON:SC/PC OR LC/PC COM:SC/APC OR LC/APC |
|||
PON to COM port insertion loss |
≤ 1.0 |
dBm |
||
C/N |
dB |
≥ 50 |
Test condition according to GT/T 184-2002. |
|
C/CTB |
dB |
≥ 63 |
||
C/CSO |
dB |
≥ 63 |
||
Power supply voltage |
V |
A:AC100V - 260V (50 Hz~60Hz) B:DC48V(50 Hz~60Hz) C:DC12V(50 Hz~60Hz) |
||
Operating temperature range |
°C |
-10 - +42 |
||
Maximum operating relative humidity |
% |
Max 95% no condensation |
||
Maximum storage relative humidity |
% |
Max 95% no condensation |
||
Dimension |
mm |
483(L)×440(W)×88(H) |
4.2 Model and Power Comparison Table
Model |
Total output power dBm |
Output ports number |
Output power per port dBm |
ADD WDM |
EYA-4 -18 |
25 |
4 |
18 |
17 |
EYA-4 -19 |
26 |
4 |
19 |
18 |
EYA-4 -20 |
27 |
4 |
20 |
19 |
EYA-4 -21 |
28 |
4 |
21 |
20 |
EYA-4 -22 |
29 |
4 |
22 |
21 |
EYA-4 -23 |
30 |
4 |
23 |
22 |
EYA-4 -24 |
31 |
4 |
24 |
23 |
EYA-8 -15 |
25 |
8 |
15 |
14 |
EYA-8 -16 |
26 |
8 |
16 |
15 |
EYA-8 -17 |
27 |
8 |
17 |
16 |
EYA-8 -18 |
28 |
8 |
18 |
17 |
EYA-8 -19 |
29 |
8 |
19 |
18 |
EYA-8 -20 |
30 |
8 |
20 |
19 |
EYA-8 -21 |
31 |
8 |
21 |
20 |
EYA-8 -22 |
32 |
8 |
22 |
21 |
EYA-8 -23 |
34 |
8 |
23 |
22 |
EYA-16 -15 |
29 |
16 |
15 |
14 |
EYA-16 -16 |
30 |
16 |
16 |
15 |
EYA-16 -17 |
31 |
16 |
17 |
16 |
EYA-16 -18 |
32 |
16 |
18 |
17 |
EYA-16 -19 |
33 |
16 |
19 |
18 |
EYA-16 -20 |
34 |
16 |
20 |
19 |
EYA-16 -21 |
35 |
16 |
21 |
20 |
EYA-16 -22 |
36 |
16 |
22 |
21 |
EYA-32 -15 |
32 |
32 |
15 |
14 |
EYA-32 -16 |
33 |
32 |
16 |
15 |
EYA-32 -17 |
34 |
32 |
17 |
16 |
EYA-32 -18 |
35 |
32 |
18 |
17 |
EYA-32 -19 |
36 |
32 |
19 |
18 |
EYA-32 -20 |
37 |
32 |
20 |
19 |
EYA-32 -21 |
38 |
32 |
21 |
20 |
EYA-32 -22 |
39 |
32 |
22 |
21 |
EYA-32 -2 3 |
40 |
32 |
2 3 |
22 |
EYA-32 -2 4 |
41 |
32 |
2 4 |
2 3 |
From PON Port to COM Port have 1dBm insert loss& 1310nm and 1490nm.
5. External Function Description
5.1 Front Panel Description
​
5.2 Rear Panel Description
​
5.2.1 DC Power Module Introduction
​
1 |
Mounting screws |
2 |
+ Positive terminal block |
3 |
- Negative terminal block |
6.1 Main Menu
​
Name |
Display |
Description |
System Starting |
xxxxxxx |
Manufacturers’ logo |
xxxxxxx |
Equipment model |
|
xxxxxxx |
||
Suspend Page |
In: xx.xout: xx.x Unit: dBm |
Display the optical input / output power |
Main Page |
1.Disp Parameters |
Entry of parameter display menu |
2.Set Parameters |
Entry of parameter setup menu |
|
3.Alarm Status |
Entry of alarm information menu |
6.2 Display Menu
​
1.Disp Parameters |
Input Power: xx.x dBm |
Input power, accurate to 0.1 dBm |
Output Power: xx.x dBm |
Output power,accurate to 0.1 dBm |
|
Pump1 Power: xx.xdBm |
Power of pump1, accurate to 0.1 dBm |
|
Pump1 Bias: x.x A |
Bias current of pump1, accurate to 0.1 A |
|
Pump1 Temper: xx.x°C |
Temperature of pump1, accurate to0.1°C |
|
Pump1 Cooling: x.xx A |
Cooling current of pump1, accurate to 0.01 A |
|
Pump2 Vol: x.x V |
Drive voltage of pump2, accurate to 0.1 V |
|
Pump2 Bias: x.x A |
Bias current of pump2, accurate to 0.1 A |
|
* Pump2 Temper: xx.x ℃ |
Temperature of pump2, accurate to 0.1 °C |
|
* Pump2 Tec Vol: x.x V |
Cooling voltage of pump2, accurate to 0.1 V |
|
* Pump2 Cooling: x.xx A |
Cooling current of pump2, accurate to 0.01 A |
|
* TEC Vol: x.x V |
The first stage voltage of pump2 cooler, 0.1 V |
|
+5V Read: x.x V |
+5V power supply voltage , accurate to 0.1 V |
|
-5V Read: -x.x V |
-5V power supply voltage , accurate to 0.1 V |
|
Box Temper: xx.x°C |
Box temperature, accurate to0.1 °C |
|
S/N: xxxxxxxx |
Device serial number |
|
IP Address: xxx.xxx.xxx.xxx |
IP address |
|
Subnet Mask:xxx.xxx.xxx.xxx |
Subnet mask |
|
Net Gateway:xxx.xxx.xxx.xxx |
Gateway |
|
Mac: xxxxxxxxxxxx |
Physical address |
|
Trap1: xxx.xxx.xxx.xxx |
trap1 address |
|
Trap2: xxx.xxx.xxx.xxx |
trap2 address |
|
Software Version: Vx.xx.x.x |
Firmware version number |
6.3 Setup Menu
​
2.Set Parameters |
Set Low Input Threshold |
Set the low optical input power alarm threshold, range -3.0~10.0dBm |
Set High Input Threshold |
Set the high optical input power alarm threshold , range -3.0~10.0dBm |
|
*Set Output ATT |
Set the optical output power attenuation |
|
Set Local IP Addr |
Set IP address |
|
Set Subnet Mask |
Set subnet mask |
|
Set Gateway |
Set gateway |
|
Set Trap1 Address |
Set trap1 |
|
Set Trap2 Address |
Set trap2 |
|
Set Buzzer cfg |
Set the switch of beeper |
|
Restore Factory config |
Restore the factory configurationset content as shown above |
The ultra-high-power output EDFA no the “*” menu.
6.4 Warning menu
3.Alarm Status
|
Input Status: xxx |
xxx= LOLOW: |
|
xxx= LOW: |
Low optical input power alarm |
||
xxx= HIGH: |
High optical input power alarm |
||
xxx= HIHIGH: |
Very high optical input power alarm |
||
Output Status: xxx |
xxx= LOLOW: |
Very low optical output power alarm |
|
xxx= LOW: |
Low optical output power alarm |
||
xxx= HIGH: |
High optical output power alarm |
||
xxx= HIHIGH: |
Very high optical output power alarm |
||
Pumpx Power: xxx |
xxx= LOLOW: |
Very low power of pump x alarm |
|
xxx= LOW: |
Low power of pump x alarm |
||
xxx= HIGH: |
High power of pump x alarm |
||
xxx= HIHIGH: |
Very high power of pump x alarm |
||
Pumpx Bias: xxx |
xxx= LOLOW: |
Very low bias current of pump x alarm |
|
xxx= LOW: |
Low bias current of pump x alarm |
||
xxx= HIGH: |
High bias current of pump x alarm |
||
xxx= HIHIGH: |
Very high bias current of pump x alarm |
||
Pumpx Temper: xxx |
xxx= LOLOW: |
Very low temperature of pump x alarm |
|
xxx= LOW: |
Low temperature of pump x alarm |
||
xxx= HIGH: |
High temperature of pump x alarm |
||
xxx= HIHIGH: |
Very high temperature of pump x alarm |
||
Pumpx Tec: xxx |
xxx= LOLOW: |
Very low cooling current of pump x alarm |
|
xxx= LOW: |
Low cooling current of pump x alarm |
||
xxx= HIGH: |
High cooling current of pump x alarm |
||
xxx= HIHIGH: |
Very high cooling current of pump x alarm |
||
+5V Status: xxx |
xxx= LOLOW: |
Very low +5V DC power supply alarm |
|
xxx= LOW: |
Low +5V DC power supply alarm |
||
xxx= HIGH: |
High +5V DC power supply alarm |
||
xxx= HIHIGH: |
Very high +5V DC power supply alarm |
||
-5V Status: xxx |
xxx= LOLOW: |
Very low -5V DC power supply alarm |
|
xxx= LOW: |
Low -5V DC power supply alarm |
||
xxx= HIGH: |
High -5V DC power supply alarm |
||
xxx= HIHIGH: |
Very high -5V DC power supply alarm |
||
Device Temper: xxx |
xxx= LOLOW: |
Very low chassis temperature alarm |
|
xxx= LOW: |
Low chassis temperature alarm |
||
xxx= HIGH: |
High chassis temperature alarm |
||
xxx= HIHIGH: |
Very high chassis temperature alarm |
7.1Communication Interface Description
​
1: No Connect |
2: TX |
3: RX |
4: No Connect |
5: GND |
6: No Connect |
The serial communication uses the sscom App, bit and the baud rate is19200.
​
LAN communication interface
Adopt RJ45 standard connector, the pin definitions as follow:
​
1: TX+ |
2: TX- |
3: RX+ |
4: No Connect |
5: No Connect |
6: RX- |
​
7.2.2 Support web browsing SNMP function
​
Device Status:
​
Device Settings:
​
Alarm Status
​
Alarm Properties
​
Network Settings
​
Change Password
​
Reset Settings
​
copyright © NEPS Technologies Pvt. Ltd. 2015-2024